Zero-phase current transformer - List of Manufacturers, Suppliers, Companies and Products

Zero-phase current transformer Product List

1~5 item / All 5 items

Displayed results

Zero-phase transformer for busbar (ZCT) "KGB-□"

ZCT for busbars used with leakage current alarms. A product with good performance and price. ★★★ Instruments for distribution boards, control panels, sub-distribution boards, and panels.

It is designed to be installed on power lines under 600V, allowing the primary side of the current transformer to carry the total circuit current, with the vector sum of the currents output on the secondary side. The output current value is measured at the input of the leakage alarm receiver. Features: - Designed with dimensions categorized by the type of applicable circuit breakers, optimizing space utilization. - The structure is designed so that the plastic surface does not touch the busbar after assembly, minimizing thermal deformation during busbar overheating. For inquiries, please contact "lightstar_1979@yahoo.co.jp".

  • Other measuring instruments
  • Substation equipment
  • Power distribution and control panels

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

SGR Busbar Zero Sequence Current Transformer (ZCT) 'KGB-□S'

ZCT for busbars used with leakage current alarms. A product with good performance and price. ★★★ Instruments for distribution boards, control panels, sub-distribution boards, and panels.

This device is designed to be installed on power lines below 600V, allowing the primary side of the current transformer to carry the total circuit current, with the vector sum of the currents output on the secondary side. The output current value is measured at the input of the leakage alarm receiver. Features: - Designed with dimensions categorized by the type of applicable circuit breaker, optimizing space utilization. - Constructed to ensure that the plastic surface does not contact the busbar after assembly, minimizing thermal deformation during busbar overheating. This product is a ZCT for SGR. For inquiries, please contact "lightstar_1979@yahoo.co.jp".

  • Other measuring instruments
  • Substation equipment
  • Power distribution and control panels

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Zero-phase current transformer (ZCT) for electric wires 'KGC-□'

ZCT used with leakage current alarms. It is a product with good performance and price. ★★★ Instruments for distribution boards, control panels, sub-distribution boards, and panels.

It is designed to be installed on a wire route under 600V AC, allowing the primary side of the current transformer to carry the total circuit current, with the vector sum of the currents output on the secondary side. The output current value is measured at the input of the leakage alarm receiver. Features: - The shape of the lower section of the penetration is designed to be flat to minimize the curvature of the penetrating wire. - The height of the penetration section is designed to be 45mm, taking into account the duct height of 40mm. For inquiries, please contact "lightstar_1979@yahoo.co.jp".

  • Other measuring instruments
  • Substation equipment
  • Power distribution and control panels

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

SGR power line zero-phase current transformer (ZCT) 'KGC-□S'

ZCT used with leakage current alarms. It is a product with good performance and price. ★★★ Instruments for distribution boards, control panels, sub-distribution boards, and panels.

This device is installed on power lines below 600V, allowing the primary side of the current transformer to carry the total circuit current, with the vector sum of the currents output on the secondary side. The output current value is measured at the input of the leakage current alarm receiver. Features: - The shape of the lower section of the penetration is designed to be flat to minimize the curvature of the passing wire. - The height of the penetration section is designed to be 45mm, considering the duct height of 40mm. This product is a ZCT for SGR. For inquiries, please contact "lightstar_1979@yahoo.co.jp".

  • Other measuring instruments
  • Substation equipment
  • Power distribution and control panels

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration